Pure Sine Wave Inverter DC 12V/24V to AC 220V — 2000W / 3000W / 4000W / 5000W Solar Power Converter
Important installation and wiring notes: - This inverter is not suitable for grid connection. Do not connect the AC output to mains supply or touch the AC output conductors to the utility grid. - Both AC output lines from the inverter are live; there is no dedicated earth/ground on these outputs. Do not use either AC output conductor as a ground wire. - Connect the inverter directly to the load. Do not insert an air switch, residual current device (RCD/GFCI) or other protection device between the inverter and the load — placing such devices in-line can prevent proper operation and may damage the inverter. - The inverter’s pure inductive load capacity is 95%. Battery and DC cabling guidance: - The battery paired with this inverter can deliver more energy than the instantaneous power consumption of the connected equipment. - Keep the DC cable run from the battery to the inverter as short as possible and use the original wiring supplied. Extending the battery leads is discouraged because longer runs require a much larger conductor to avoid voltage drop and insufficient input current/voltage. - If you must extend the DC cable, the extension conductor diameter should be approximately doubled compared with the original cable. The manufacturer recommends keeping the total battery-to-inverter cable length under 1 meter whenever possible to ensure safe and reliable operation.