2500W Pure Sine Wave Hybrid Solar Inverter (12/24/36/48V → 100/110/120/220/230/240V) LCD + 30A PWM Solar Charger
Overview: Off-grid pure sine wave hybrid inverter providing 2500W continuous output and 5000W surge capacity. Available for 12V, 24V, 36V or 48V DC input and configurable to AC outputs of 100/110/120V or 220/230/240V at 50Hz or 60Hz. Unit includes an LCD display and a built-in 30A PWM solar charge controller. Inverter electrical & operational specifications: - DC Voltage options: 12V or 24V or 36V or 48V - DC input voltage ranges: 10-15VDC or 21-30VDC or 42-60VDC - No load current draw: <1A - Efficiency: >90% - DC connector: Cables with clips or car adaptor - AC Voltage options: 100/110/120V AC or 220/230/240V AC - Continuous Power: 2500W; Surge Power: 5000W - Waveform: Pure Sine Wave - Frequency: 50HZ or 60HZ - AC regulation: 3% - Total Harmonic Distortion (THD): <5% Protection and automatic shutoffs: - Low voltage alarm: 10DC ±0.5V or 20.5DC ±1V or 44VDC ±1V - Low voltage shut down: 9.5DC ±0.5V or 19.5DC ±1V or 42VDC ±1V - Over voltage shut down: 15.5V or 30.5V or 61.2V - Overload: shuts off output - Over thermal: shuts off output automatically - Fuses: short circuit protection - Over current protection and surge protection included Physical, environmental and start/cooling details: - Start: Soft start - Cooling method: Cooling fan - Working temperature: Between -10°C and +50°C - Working humidity: 20% ~ 90% RH non-condensing - Storage temperature: Between -30°C and +70°C - Machine size (mm): 350 * 240 * 220 - Packing size (mm): 470 * 300 * 250 - Net Weight (kgs): 6.5KG; Gross Weight (kgs): 9KG Solar charger (controller) specifications: - Rated current: 30A - Rated voltage: 12V / 24V - Open circuit voltage of solar panel: 50V - Low Voltage Disconnection (LVD): 10.7V / 21.4V - Float voltage: 13.8V / 27.6V - Low Voltage Reconnection (LVR): 12.5V / 25.0V - No load loss: 30mA - Loop voltage drop: 170mV - Charging mode: PWM mode - Temperature compensation: -4mV / Cell / °C - Protection systems: thermal protection, overload protection, over voltage protection, under voltage protection, low voltage protection alarm Fault indication and built-in protections: The inverter includes an LED indicator to signal faults. Protection functions include the LED indicator plus the following safeguards: 1. Short circuit protection: inverter stops if load creates a short circuit. 2. High temperature protection: inverter will stop if ambient/ internal temperature exceeds rated limits and cannot be dissipated. 3. High voltage protection: inverter stops if battery voltage exceeds rated input. 4. Low voltage protection: inverter will cut input to protect itself when battery voltage falls below the rated threshold. 5. Surge protection: protects internal electronics from DC high-voltage surges. 6. Overload protection: inverter stops if appliance power exceeds inverter capacity. 7. Over current protection: board protection components will cut off if appliance current exceeds inverter limits. 8. Fuse protection: when appliance resistance is greater than the inverter, the fuses on the socket will operate automatically.
Shipping & Returns
Shipping & Returns







